To replace the component, reverse the removal procedure.
Replacing the Flexible Slot power supply backplane
Prerequisites
Before you perform this procedure, make sure that you have a T-15 Torx screwdriver available.
Procedure
1. Power down the server.
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Disconnect all peripheral cables from the server.
4. Do one of the following:
If the server is in tower mode: Place the server on its side with the access panel facing up.
If the server is in rack mode, do one of the following:
Extend the server from the rack.
Remove the server from the rack.
5. Remove the front bezel.
6. Remove the access panel.
7. If installed, remove the air baffle.
8. Disconnect all the power supply cable from the backplane.
9. Remove the power supply from the power supply cage.
Removal and replacement procedures 71