Procedure
1. Power down the server.
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Disconnect all peripheral cables from the server.
4. Do one of the following:
• If the server is in tower mode: Place the server on its side with the access panel facing up.
• If the server is in rack mode, do one of the following:
◦ Extend the server from the rack.
◦ Remove the server from the rack.
5. Remove the front bezel.
6. Remove the access panel.
7. If installed, remove the air baffle.
8. Disconnect all power supply cables.
9. Remove the power supply.
To replace the component, reverse the removal procedure.
Removing and replacing a Flexible Slot power supply
WARNING: To reduce the risk of personal injury from hot surfaces, allow the power supply or power
supply blank to cool before touching it.