To replace the component, reverse the removal procedure.
Removing and replacing the M.2/dedicated iLO/serial port
kit
Removing and replacing the M.2/dedicated iLO/serial port enablement
board
CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all
PCI slots have either an expansion slot cover or an expansion board installed.
CAUTION: Before replacing a DIMM, expansion board, or other similar PCA components due to a
perceived hardware error, make sure first that the component is firmly seated in the slot. Do not
bend or flex circuit boards when reseating components.
Prerequisites
Before you perform this procedure, make sure that you have the following items available:
T-15 Torx screwdriver
Hex nut screwdriver
Procedure
1. Power down the server.
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Disconnect all peripheral cables from the server.
4. Do one of the following: