Shenzhen Hpmont Technology Co., Ltd Chapter 6 Function Introduction
HD5L Series Controller User Manual ―65―
6.2.6 Group F05 Speed Parameters
Code Name Description Range
factory setting
F05.00 Multi-speed 0 0.000
F00.02
0.000m/s
F05.02 Multi-speed 2 0.000
F00.02
0.000m/s
F05.04 Multi-speed 4 0.000
F00.02
0.000m/s
F05.06 Multi-speed 6 0.000
F00.02
0.000m/s
F05.00-F05.07 define the MS running speed which use in MS run mode. F00.02 defines the elevator
rated speed.
It defines the elevator’s running speed in the inspection mode.
It defines the elevator’s running speed in the battery driven run mode.
Up forced Dec detection value
0.0-100.0 (F00.02)【97.0%】
It defines the speed detection value at the forced
switch action.
• After forced switch act, the running speed exceeds
Dec detection value, and decelerate to F05.22
(creeping speed) according to F03.12 (abnormal
Dec speed).
• Properly set this parameter to avoid climbing
elevator at elevator up.
Down forced Dec detection value
0.0-100.0 (F00.02)【97.0%】
To avoid plunging elevator at elevator down. Refer to parameter F05.10.
Shaft top space
Contact board
Top floor
Car
Up forced
Dec switch