Step 4 Connect the cables and power on the quorum server.
Step 5 After the quorum server is powered on, reinstall and congure the quorum server
software.
For details, see the 
BC&DR Solution Product Documentation (Active-Active DCs)
.
----End
Follow-up Procedure
Log in to the quorum server, run the qsadmin command to go to the
conguration page of the quorum server software, and run the show server_ip
command to check whether the connection between the quorum server and
storage devices is in Established state.
Q2qumrom:~ # qsadmin 
start main! 
Waiting for connecting to server... 
admin:/>show server_ip          
Index     Server IP           Server Port         
-----     ---------------     ---------------         
1         192.168.6.31        30002         
2         192.168.7.31        30002          
Index     Local IP            Local Port          Remote IP           Remote Port         State         
-----     ---------------     ---------------     ---------------     ---------------     ---------         
0         192.168.6.31        30002               192.168.6.17        44510             Established         
1         192.168.6.31        30002               192.168.6.18        36836             Established         
2         192.168.7.31        30002               192.168.7.16        57416             Established         
3         192.168.7.31        30002               192.168.7.28        49752             Established        
● If yes, the quorum server is added successfully.
● If no, the quorum server fails to be added. Check whether the IP address of
the quorum server is correct.
OceanStor V5 Series
Parts Replacement 7 Replacing FRUs
Issue 15 (2019-12-30) Copyright © Huawei Technologies Co., Ltd. 260