NOTE
Other tabs on this page, such as AV, CNC, and IPS, are signature databases, irrelevant to content security
feature component packages.
The content security feature component package to be loaded must be compatible with the system
software.
----End
2.2.4.3 Preparing the Upgrade Environment
Prerequisites
Before the upgrade, you need to log in to the CLI of the USG9500 to prepare the upgrade
environment.
By default, IP address 192.168.0.1 has been set for interface GigabitEthernet 0/0/0 on the
MPU of the USG9500.Or another accessible IP address on the device has been set.
l You can use this IP address and the default user name admin and password Admin@123
to log in to the CLI of the USG9500 through Telnet.
l If the Telnet configuration is canceled or you desire to use SSH for the login, log in to
the USG9500 from the console port to construct the Telnet or SSH environment. For
details, see chapter "Appendix: Establishing the Upgrade Environment Through the
Console Port." You are advised to use SSH to log in to the USG9500 to secure data
transfer.
Preparing Upgrade Tools
It is recommended that you prepare the following tools for upgrade:
l Login tool
Login tools help you log in to the device through the console port, Telnet, or SSH. This
document uses the tool in Windows as an example. In practice, it is recommended that
you use a legitimate third-party tool, for example, SecureCRT, to log the upgrade
operations in detail.
l File comparison tool
File comparison tools help you compare the configuration files before and after upgrade
for configuration loss. In practice, it is recommended that you use a legitimate third-
party tool, for example, Beyond Compare.
l Inspection tool
Inspection tools, SmartKit NSE2700 for example, help you comprehensively inspect the
device after upgrade to ensure no problems exist. In practice, it is recommended that you
use a certain version of the inspection tool that is applicable the target version.
Preparing the Environment for the Upgrade Through CLI
The key to the upgrade through the CLI is how to transfer the version software to CF card 1
of the USG9500. Currently, the following modes are supported:
l FTP mode with the USG9500 as the FTP server
l FTP mode with the USG9500 as the FTP client
HUAWEI USG6000&USG9500
Upgrade Guide
2 USG9500
Issue 01 (2018-01-16) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
130