With the servo enabled, attach the adhesive weight using
the weight amount shown for the right weight plane on
the screen.
TruWeight® shows the operator exactly how to place the
weights on the wheel. Place them exactly as displayed
on the screen. Close the safety hood to perform a check
spin.
Left and right weight plane displays should show “OK”
after check spin.
MIXED WEIGHTS balancing procedure is complete.
3.8.3. Balancing Procedure Using Adhesive (Tape) Weights
Verify that the wheel is clean and free of debris.Remove
all previous weights. Mount tire/wheel assembly.
Close the hood to perform a balance spin. Information is
computed automatically.
As the wheel is spinning, the amount(s) of corrective
weight(s) needed will be shown on the screen. This time
can be used to nd and prepare the needed weights.
NOTICE
Once weight amounts are shown on the screen,they can be toggled to display either ounces or grams by
pressing the “oz” or “g” graphic shown after the weight amount.
After wheel comes to a complete stop, raise the safety
hood.
NOTICE
If Auto Hood is enabled, the hood will raise
automatically.
The HD Elite® Servo-Activated Laser automatically
locates adhesive weight positioning.
The laser weight locator automatically displays a vivid
line after a wheel has been spun. The laser turns o when
the wheel is spun again.
HD Elite Wheel Balancer
Page 27 of 51