103
4. System Setup
( 7 ) Pushrod before part off fast speed value setting(HEX bar )
( 8 ) Pushrod before part off slow speed value setting(HEX bar )
( 9 ) Pushrod feeding speed setting
Fast speed setting for HEX bar to part off position
( torque mode )
speed setting ranges: 200- 1000 (130- 650mm/sec)
Factory setting data: 400 ( 260mm/sec
Slow speed setting for HEX bar to part off position
( torque mode )
speed setting ranges: 80- 300 (52- 195mm/sec)
Factory setting data : 200(130mm/sec)
Select 9. < Pushrod feeding speed
setting >
(1) Feed to turret speed setting
(2) Feed to position speed setting