107
4. System Setup
( 10 ) Pushrod / Flag retract fast speed value setting
( 11 ) Pushrod / Flag retract slow speed value setting
Fast speed setting to pushrod/Flag retract
( position mode )
speed setting ranges: 5000- 16000
(500 -1600mm/sec)
Factory setting data : 16000(1600mm/sec)
Slow speed setting to pushrod/Flag retract
( position mode )
speed setting ranges:1000- 5000
(100- 500mm/sec)