( B ) Feed to position speed setting
Select 2.< Feed to position speed setting >
Fast speed setting for pushrod to reach 20mm bar
stock .
speed setting ranges: 1000- 7000 (100 -
700mm/sec)
Factory setting data : 5000 (500mm/sec)
Slow speed setting to push bar to require position
Note : lower the speed to avoid positioning error.
speed setting ranges: 200- 1000 (20 -100mm/sec)
Factory setting data : 800 (80mm/sec)