MAINTENANCE
HT4400 Instruction Manual 5-31
3
Phase Loss Detection Board PCB21 - Status Indicators and Operation
Operation
The phase loss detection circuit looks at the incoming voltage and verifies that the voltages between the 3-wire
inputs are within +/- 15% of each other.
After contactor CON1 closes, opto-coupler U1 on PCB21 is activated, shorting pins 1&2 of PL1 together
and illuminating LED1.
If LED1 does not illuminate:
Verify that voltages across points A B and C, phase-to-phase are approximately 255 VAC. If voltages
are not within +/- 15%, LED1 will not illuminate. Check the incoming line voltage and the contacts on
CON1.
Check PCB21 fuses F1-F3. If any of the fuses are open, then PCB21 is faulty.
Check jumper on P2 and verify that the jumper is set for 265V.
Phase Loss Board PCB21 location on chopper CH4 -
See page 6-3 for location of CH4
F1
A
F2
B
F3
U1
C
LED1
P2
P2 Jumper
for 265 V