SitePlanning‐OverallDimensions
12
5 SitePlanning
5.1 OverallDimensions
Figure3:ChillerOverallDimensions
5.2 LocationConsiderations
5.2.1 Environmen talRequirem ents
Table4definestheenvironmentalrequirementsforproperchilleroperation.Forconsiderationofspecial
applicationsthatdonotadheretotherequirementsinthetablebelowcontactGlenDimpl exThermalSolutions
(GDTS)engineeringforreview.
Table4:ChillerOperatingEnvironmentalRequirements
Criterion Value
Location Indoorsonly
MinimumTemperature 14°F(10°C)
MaximumTemperature 104°F(40°C)
MinimumRelativeHumidity 10%
MaximumRelativeHumidi ty 90%
MinimumAltitude Atsealevel
MaximumAltitude 8,000ft(2,4384m)abovesealevel

Hypertherm, Inc. Part Number: 810540