65A Unshielded Air flow rate - slpm/scfh
Mild Steel
Hot 160 / 340
Cold 220 / 470
Metric
Material
Thickness
Torch-
to-Work
Distance
Initial Pierce
Height
Pierce
Delay
Time
Recommended Maximum
Cut
Speed
Voltage
Cut
Speed
Voltage
mm mm mm % seconds (mm/min) Volts (mm/min) Volts
2
2.0
5.0 250
0.1 6050 117 9200 116
3 0.2 5200 118 7900 117
4
0.5
4250 118 6550 117
6 2550 120 4100 119
8 1620 123 2800 120
10 6.0 300 0.7 970 127 1880 122
12
Edge Start
760 129 1400 124
16 500 134 800 128
20 280 138 560 132
English
Material
Thickness
Torch-
to-Work
Distance
Initial Pierce
Height
Pierce
Delay
Time
Recommended Maximum
Cut
Speed
Voltage
Cut
Speed
Voltage
in in % seconds ipm Volts ipm Volts
16GA
0.08
0.20 250
0.1
255 116 385 115
10GA 190 118 290 117
3/16 in 0.2 135 119 215 118
1/4 in 0.5 90 120 145 119
3/8 in 0.24 300 0.7 40 126 78 121
1/2 in
Edge Start
27 130 50 125
5/8 in 20 134 32 128
3/4 in 13 137 22 131