TORCH SETUP
powermax
65/85
Operator Manual 3-49
65A Unshielded Air flow rate - slpm/scfh
Stainless Steel
Hot 160 / 340
Cold 220 / 470
Metric
Material
Thickness
Torch-
to-Work
Distance
Initial Pierce
Height
Pierce
Delay
Time
Recommended Maximum
Cut
Speed
Voltage
Cut
Speed
Voltage
mm mm mm % seconds (mm/min) Volts (mm/min) Volts
2
2.0
5.0 250
0.1 7950 117 12800 119
3 0.2 6600 118 10600 119
4
0.5
5050 119 8200 119
6 2300 121 3800 120
8 0.7 1400 123 2400 121
10 6.0 300 0.7 920 126 1550 123
12
Edge Start
710 130 1150 127
16 480 135 630 132
English
Material
Thickness
Torch-
to-Work
Distance
Initial Pierce
Height
Pierce
Delay
Time
Recommended Maximum
Cut
Speed
Voltage
Cut
Speed
Voltage
in in % seconds ipm Volts ipm Volts
16GA
0.08
0.20 250
0.1
340 116 540 118
10GA 235 118 380 119
3/16 in 0.2 150 120 240 119
1/4 in 0.5 75 121 125 120
3/8 in 0.24 300 0.7 38 125 65 122
1/2 in
Edge Start
25 132 40 128
5/8 in 19 135 25 132

Table of Contents

Other manuals for Hypertherm Powermax 85

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm Powermax 85 and is the answer not in the manual?

Hypertherm Powermax 85 Specifications

General IconGeneral
Gas SupplyClean, dry, oil-free air or nitrogen
Cooling MethodFan-cooled
Input Voltage200-600V, 3-phase
Current Output25-85 A
Duty Cycle60% @ 85 A
Recommended Gas Inlet Flow Rate/Pressure6.7 scfm @ 85 psi
Cutting Capacity (Recommended)1" (25 mm)
Gas TypeAir/Nitrogen