TORCH SETUP
3-50
powermax
65/85
Operator Manual
65A Unshielded Air flow rate - slpm/scfh
Aluminum
Hot 160 / 340
Cold 220 / 470
Metric
Material
Thickness
Torch-
to-Work
Distance
Initial Pierce
Height
Pierce
Delay
Time
Recommended Maximum
Cut
Speed
Voltage
Cut
Speed
Voltage
mm mm mm % seconds (mm/min) Volts (mm/min) Volts
2
2.0
5.0 250
0.1 7750 123 14200 123
3 0.2 6550 124 12000 123
4
0.5
5400 125 9500 123
6 3000 127 4850 124
8 0.7 1800 130 3000 126
10 6.0 300 0.7 1100 133 2050 127
12
Edge Start
900 135 1560 129
16 600 139 880 132
English
Material
Thickness
Torch-
to-Work
Distance
Initial Pierce
Height
Pierce
Delay
Time
Recommended Maximum
Cut
Speed
Voltage
Cut
Speed
Voltage
in in % seconds ipm Volts ipm Volts
1/16 in
0.08
0.20 250
0.1
325 122 590 122
1/8 in 175 125 300 123
1/4 in 0.5 100 127 160 124
3/8 in 0.24 300 0.7 45 132 85 127
1/2 in
Edge Start
32 136 55 129
5/8 in 24 138 35 132