www.hysecurity.com Display & Menu Options D0559 Rev. A 47
settIng tHe Close tImer
As an added security measure, set the Close Timer. This ensures that the Security gate closes automatically within
a reasonable time frame, after all loops are cleared.
The Close Timer assigns how many seconds will pass before the gate operator initiates closure of a fully opened
gate after all open commands and reversing sensor inputs have ceased and loops cleared. Every gate operator
needs to have the close timer set to a specic number of seconds (for example, 5 seconds) unless a hard-wired
closing device is connected to the unit, such as a “hold to close” push button station.
To adjust the time (1 to 99 seconds) it takes before the operator initiates gate closure, take the following steps:
1. At a gate status display, press the Menu button twice. This accesses the User Menu and the Close Timer
display appears.
NOTE: If you want gate personnel to operate the gate with the Hold to Close feature found in some push
button stations, then set the Hold to Close menu item to 1. When the Hold to Close menu item is active
(set to 1), the Close Timer menu item is unavailable.
2. Use the Select, and then Next or Previous buttons to navigate and change the number of seconds
appearing on the display. Refer to Menu Mode Navigation on page 36.
3. To exit the User Menu, press the Menu button. The gate status appears in the display indicating you have
returned to Run Mode.