Table 4: FIDs and FRUs (continued)
Reporte
d FID
FRUs FRU name or description Prob-
ability
Page reference or instruction
59 Decryption error - Error was detected during the decryption of data
83 Microcode 25% “FID 84 or E6 - Isolating fault between
microcode and hardware” on page 240
- Encryption Key Manager 25% IBM External Key Manager Introduction, Planning,
and User's Guide
87 Tape cartridge 25% “FID 87 or F2 - Isolating fault between media
and hardware” on page 243
85 Drive canister 25%
“FID 85: Drive canister” on page 252
5A Encryption Key Manager failure - An unexpected status was returned by the key manager. Check the
proxy interface and the Encryption Key Manager log.
Note: This issue is not a drive or microcode problem. The customer must isolate the problem from
this symptom.
5B Encryption PROXY failure - A failure or timeout occurred on the proxy interface. Check the proxy
interface and the Encryption Key Manager log.
Note: This issue is not a drive or microcode problem. The customer must isolate the problem from
this symptom.
5F Security prohibited function - A function was attempted which is prohibited.
81 Thermal sensor detected overtemperature condition
1. If you suspect that the problem is because of environmental conditions, you can order and use a
datalogger tool (P/N 45P5917) to record ambient temperature. Contact your next level of
support for procedures to correct this condition.
2. If the environmental conditions are within specication and the problem persists, replace the
drive canister.
85 Drive canister 100%
“FID 85: Drive canister” on page 252
82 or C1 Drive voltage not within specication, the drive detects a power outage, or a power supply-cooling
fan failed
Notes:
This error can be triggered only when a tape is loaded in the drive.
This error can take up to 50 minutes to be reported after the condition is detected.
82 Power supply 88% “Power problems MAP” on page 193
EA Power supply cables 8%
“FID EA: Cables FRU kit” on page 255
85 Drive canister 4%
“FID 85: Drive canister” on page 252
83 or E5 Microcode fault
83 Microcode 100% “FID 83 or E5 - Microcode problem” on page 239
8 IBM 3592 TS1140, TS1150, TS1155, and TS1160 Tape Drives: Maintenance Information

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM 3592 and is the answer not in the manual?

IBM 3592 Specifications

General IconGeneral
BrandIBM
Model3592
CategoryStorage
LanguageEnglish

Related product manuals