Table 4: FIDs and FRUs (continued)
Reporte
d FID
FRUs FRU name or description Prob-
ability
Page reference or instruction
84 or E6 Timing problem in the microcode or the electronics, or multiple check-1 errors occurred
83 Microcode 50% “FID 84 or E6 - Isolating fault between
microcode and hardware” on page 240
85 Drive canister 40%
“FID 85: Drive canister” on page 252
82 Power supply 7% “Power problems MAP” on page 193
EA Power supply cables 3%
“FID EA: Cables FRU kit” on page 255
85 Read/write, or track-following error
87 Cartridge 5% “FID 87 or F2 - Isolating fault between media
and hardware” on page 243
85 Drive canister 95%
“FID 85: Drive canister” on page 252
86 or F2 Hardware or media fault
FID 87 or F2 that occurs while the Test Drive or Test Device diagnostic test is run, can be caused by
a drive that needs calibration. An automatic calibration step runs during the longer Test Device
diagnostic test. In addition, an automatic calibration step is run if the initial pass fails, during the
short Test Drive diagnostic test.
87 Tape Cartridge 50% “FID 87 or F2 - Isolating fault between media
and hardware” on page 243
85 Drive canister 50%
“FID 85: Drive canister” on page 252
87 or FE Cartridge problem
87 Tape cartridge 95% “FID 87 or F2 - Isolating fault between media
and hardware” on page 243
85 Drive canister 5%
“FID 85: Drive canister” on page 252
8A, D0,
or D8
Degraded hardware - Customer jobs continue to run, but with degraded performance. Complete the
action, at your earliest convenience.
85 Drive canister 100%
“FID 85: Drive canister” on page 252
AA General conguration problem
- Conguration problem 90%
1. Reset drive
2. Go to “Installation checkout” on page 174.
- Invalid drive serial number 10% Enter valid drive serial number. Go to “CE DRV
Ser No menu (CE Offline Mode)” on page 121.
AC Worldwide ID is blank, is invalid, or cannot be read
85 Drive canister - If you are installing a new drive, contact your
next level of support and report this problem. If it
is an existing drive, try to reenter the WWID (see
“Setting WW names” on page 208). Go to -
“FID 85: Drive canister” on page 252
Start 9