62
Responding to error codes
1162
Onboard Serial Port
Conflict(s)
Enter Setup and do any of the following:
Change the onboard serial port I/O address and IRQ or
disable it.
Change the add-on card serial port I/O address and
IRQ then reboot the system.
For information on the Setup Utility options, see the
Aptiva online help.
1755
Hard Disk Drive(s) Write
Protected
Enter Setup and make sure that the Hard Disk Drive
parameter is set to
Normal
. For information on the
Setup Utility options, see the Aptiva online help.
1762
Onboard IDE Channel
Address Conflict(s)
1
Remove all the add-on cards in the system.
2
Power on the system to see if it works without the
cards.
3
Re-install the cards one by one to determine which of
the cards caused the error.
4
After determining the defective card or cards, enter
Setup and set the Reset Resource Assignments
parameter to
Yes
, then reboot the system.
5
If the problem still shows, set the Onboard IDE
Primary/Secondary Channel parameter to
Disabled
,
then reboot the system.
For instructions on installing add-on cards, see the
Aptiva online help.
Error code and description Here’s what to do...
If any of these problems continue after taking the actions
listed, run the diagnostics programs that came with your
computer. If you need service, see “HelpWare support and
services” on page 79.
66xarg.book : 66xach3.fm Page 62 Tuesday, June 30, 1998 10:18 AM

Table of Contents

Other manuals for IBM Aptiva

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM Aptiva and is the answer not in the manual?

IBM Aptiva Specifications

General IconGeneral
BrandIBM
ModelAptiva
CategoryDesktop
LanguageEnglish

Related product manuals