If
an
SRC
is
displayed, perform the procedure indicated by the SRC.
If
the IPL is
not
successful, go to
step 2
on
page 1-6.
If
the
IPL
is successful,
run
system test to verify
that
the problem is fixed.
Go
to
"328 Service Procedures under
SSP"
on
page 3-10.
2.
Reload the
SSP
diskettes to disk drive A and perform an
IPL
from disk. See the following:
a. Reference procedure "322 Reloading the SSP Diskettes"
on
page 3-8.
If
an
SRC is displayed
or
if
the IPL
is
not
successful, continue with the next action.
If
the IPL is
successful,
run
system test to verify
that
the problem is fixed.
Go
to "328 Service Procedures under
SSP"
on
page 3-10.
Notes:
a. The customer's
data
will be destroyed when you initialize the disk.
To
minimize the exposure
of
destroying customer data, read the following note.
b.
An
alternative method to initializing disk drive A is to install a new disk drive before performing step
3.
If
the new disk drive fails, use the list
of
FRUs
at
the end
of
this procedure to isolate the
problem.
It
may be necessary to reinstall the old disk drive and attempt to initialize the disk to
remove customer data.
3.
Initialize disk drive A, reload the system microcode to disk, reload the
SSP
diskettes to disk, and perform
an
IPL.
a. Insert diskette
61
in
the 5363 diskette drive. Perform
an
IPL
of
the
5363
using a select function 3,
enter a code
of
22FF,
and
press the Start Function key.
b. Select the option to initialize the disk. Follow the prompts.
c.
Reloadthe
5363 microcode ("324 Reloading the System Microcode Without Auto Configure"
on
page 3-8).
d.
Load SSP reference procedure ("322 Reloading the SSP Diskettes"
on
page 3-8).
e.
Perform
an
IPL
of
the 5363 from disk using a select function
1,
enter a code
of
0000, and press the
Start Function key.
If
the IPL is successful,
run
system test to verify
that
the problem
is
fixed ("328 Service Procedures
under
SSP"
on
page 3-10).
If
an
SRC indicated
that
the disk drive is the failing
FRU,
install a new drive. The following
FRUs
can cause
IPL
failures:
Disk drive
Disk adapter card (AIC2)
Disk cable assembly
Control storage processor card (AIG2)
Al
board
Main
storage processor cards
(AIH2and
AIJ2)
1-6
5363
Maintenance Information