Table 6. IMM2 error messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained
technician.
806f000f-22010bxx The System %1
encountered a POST
Error.
(%1 =
CIM_ComputerSystem.
ElementName)
Error Firmware BIOS
(ROM) corruption
was detected
during POST.
(Sensor = ABR
Status)
1. Make sure the server meets the
minimum configuration to start.
2. Recover the server firmware from
the backup page:
a. Restart the server.
b. At the prompt, press F3 to
recover the firmware.
3. Update the server firmware to the
latest level (see “Updating the
firmware” on page 267).
Important: Some cluster solutions
require specific code levels or
coordinated code updates. If the
device is part of a cluster solution,
verify that the latest level of code
is supported for the cluster solution
before you update the code.
4. Remove components one at a
time, restarting the server each
time, to see if the problem goes
away.
5. If the problem remains, (trained
technician) replace the system
board.
816f000f-22010bxx The System %1
encountered a POST
Error deasserted.
(%1 =
CIM_ComputerSystem.
ElementName)
Error Firmware BIOS
(ROM) corruption
was deasserted
during POST.
(Sensor = ABR
Status)
No action; information only.
806f000f-2201xxxx The System %1
encountered a POST
Error.
(%1 =
CIM_ComputerSystem.
ElementName)
Error The System
encountered a
firmware error.
(Sensor =
Firmware Error)
1. Make sure the server meets the
minimum configuration to start.
2. Update the server firmware on the
primary page.
Important: Some cluster solutions
require specific code levels or
coordinated code updates. If the
device is part of a cluster solution,
verify that the latest level of code
is supported for the cluster solution
before you update the code.
3. (Trained technician only) Replace
the system board.