Magnetic Reader Connection
The controller allows the connection of standard magnetic track 2 format cards and provision is made in the
software for a large number of formats. Formats include BIN number for ATM access control and first 4, 5 and 6
card numbers.
Magnetic Card Reader Interface:
YELLOW
GREEN
RED
BROWN
ORANGE
OUT COM IN
INLINE +5v REGULATOR
50mA MAX OUTPUT
+5V +12V
0V
0V
V+
V-C BZ L2 L1
D1/
D0/
NB
NA
Magnetic card readers are typically operated by 5 volts. Before connecting the magnetic card reader to the
controller, ensure that the supply voltage is correct and if required insert the inline 5 Volt regulator as shown in
the diagram above.
The magnetic reader connection has not been evaluated for UL/ULC applications.
Door Contact Connection
The module allows the connection of up to 4 contacts for monitoring and controlling access control doors. Each
input can be used for either the door function that is automatically assigned or as a normal input on the system.
The following example shows the connection of a normally closed door position monitoring contact to monitor the
open, closed, forced and alarm conditions of the door.
PRT-CTRL-DIN | Protege GX DIN Rail Integrated System Controller | Installation Manual 22