NanoPhotometer
®
N120/NP80/N60/N50/C40
User Manual
Version 4.3.1
Software Version 4.3.15670

Table of Contents

Questions and Answers

  • J
    John MillerAug 16, 2025
    What to do if Implen Measuring Instruments shows 'Concentration too high. Dilute sample.'?
    • R
      Rachel FosterAug 16, 2025
      If the concentration of your sample is too high for submicroliter cell measurements using Lid 250 with the C40, dilute the sample manually. This will allow you to measure within the detection range of the instrument.
  • J
    Joshua MitchellAug 19, 2025
    What to do if Implen NanoPhotometer N120 Measuring Instruments shows 'Concentration too high. Change to lid10/lid50/lid100/lid250.'?
    • K
      kyle66Aug 19, 2025
      If the concentration of the sample used is too high for submicroliter cell measurements with the utilized lid, change to the recommended lid. It is also recommended to use a new blank when changing the dilution lid.
  • S
    Sabrina CampbellAug 22, 2025
    Why does Implen NanoPhotometer N120 show an air bubble, lint residue or bad sample error?
    • J
      jamesscottAug 22, 2025
      The 'air bubble, lint residue, or bad sample' error appears when the air bubble recognition feature is on and detects an air bubble, lint residue, or a compromised sample, such as a turbid sample. To resolve this: * Check your sample. * Thoroughly clean the pedestal and mirror in the lid. * Carefully reapply the sample, using reverse pipetting to prevent air bubbles.
  • B
    Brandon DanielAug 26, 2025
    What to do if Implen Measuring Instruments says the battery is low?
    • K
      Kimberly JacksonAug 26, 2025
      If the device indicates that the battery is low, connect it to a power source.
  • H
    hinesstephenAug 28, 2025
    What to do if Implen NanoPhotometer N120 says another control device is currently connected?
    • D
      david20Aug 28, 2025
      Please close the method on the control device.
  • K
    katelynwrightAug 31, 2025
    What to do if Implen Measuring Instruments concentration is too high for the lid?
    • M
      Marc LeeAug 31, 2025
      If the concentration of your sample is too high for submicroliter cell measurements with the current lid, it is recommended to switch to the lid specified by the device. Remember to run a new blank after changing the dilution lid.
  • C
    Christian NelsonSep 3, 2025
    What to do if Implen NanoPhotometer N120 concentration is too high and says 'Dilute sample'?
    • K
      Katie JonesSep 3, 2025
      If the concentration of your sample is too high for submicroliter cell measurements using Lid 250 with the C40, dilute the sample manually. This will bring the concentration within the instrument's detection range.
  • A
    andersonrobertSep 6, 2025
    What to do if Implen NanoPhotometer N120 Measuring Instruments battery is low?
    • T
      Troy MunozSep 6, 2025
      If your Implen Measuring Instruments indicates a low battery, connect it to a power source immediately.
  • J
    Jeremy WoodwardSep 9, 2025
    Why Implen NanoPhotometer N120 says another control device is currently connected?
    • J
      Jonathan HarrisSep 9, 2025
      If you see this message on a control device, it means another control device is already connected and has an open measurement session. To resolve this, close the method on the other control device.
  • D
    David JacksonSep 12, 2025
    How to fix air bubble, lint residue or bad sample error on Implen NanoPhotometer N120 Measuring Instruments?
    • T
      tuckercynthiaSep 12, 2025
      If the air bubble recognition feature is active and detects an air bubble, lint residue, or a compromised sample (e.g., a turbid sample), inspect the sample. Clean the sample window on the pedestal and the mirror in the lid arm thoroughly. Reapply the sample carefully, using reverse pipetting to prevent air bubbles.

Implen NanoPhotometer N120 Specifications

General IconGeneral
Light SourceXenon flash lamp
Weight2.5 kg
Sample Volume0.3 - 2 µL
DisplayTouchscreen
Data OutputUSB, Ethernet
Detector2048 element CCD array
Path Lengths0.1 cm
Absorbance Accuracy± 0.003 (at 1.0 A)
Operating SystemEmbedded
Dimensions200 x 200 x 150 mm
Power Supply100 - 240 V
Optical Resolution≤ 3 nm
Photometric Accuracy± 0.003 (at 1.0 A)
Photometric Repeatability± 0.002 A