Chapter 2: General Mobile Platform Specifications
2.1 Mounting Surface
• The mounting surface must be flat within 1/16” (1.6mm)
• A 1½” (38.1mm) diameter hole is needed near the mounting surface for routing of
the control and signal cables.
2.2 Cable Lengths
• The 1800 platforms may require the settings to be adjusted on the AZ & EL axis
when cable used is greater than 50ft and the user experiences overcurrent
errors.
• Adjust speed and Low Platform Current values increasing each by one (+1.0)
until system overcurrent errors are eliminated. It is recommended that operator
contacts C-COM Support and Slow Speed settings do not exceed 9 while Low
Platform Current maximum is 10.