Chapter 2: General Mobile Platform Specifications
2.1 Mounting Surface
The mounting surface must be flat within 1/16” (1.6mm)
A 1½” (38.1mm) diameter hole is needed near the mounting surface for routing of
the control and signal cables.
2.2 Cable Lengths
The 1800 platforms may require the settings to be adjusted on the AZ & EL axis
when cable used is greater than 50ft and the user experiences overcurrent
errors.
Adjust speed and Low Platform Current values increasing each by one (+1.0)
until system overcurrent errors are eliminated. It is recommended that operator
contacts C-COM Support and Slow Speed settings do not exceed 9 while Low
Platform Current maximum is 10.