4.12 Installing Flexible Waveguide onto 1800 Mobile Platform
Procedure:
1. Connect the flexible waveguide to the OMT-TRF using the appropriate Allen Key.
Ensure the groove of the waveguide aligns with the groove of the OMT.
2. The waveguide should extend outwards from the OMT and loop UPWARDS then back
through the POL Cage opening under the Feed Arm Roll Bar. The waveguide should
travel straight towards the connector flange on the BUC. A clamp which is part of the
POL Cage will hold the Waveguide in place. Ensure the flex bend diameter is a
minimum of 6 inches.
3. Run the Waveguide through clamp and ensure screws are tightened.
4. Connect the waveguide to the BUC using the appropriate machine screws. Ensure the
groove of the waveguide aligns with the groove of the BUC.
5. This procedure can be used for all three (Ku, C Circular and C Linear Bands) version
of the POL Feed Horn Assembly.