Mobile Installation Manual Page 86 of 93
Fig. 72: Right Hand Circular Polarization
3. Fasten the 8 Allen screws attaching the polarizer flange to the OMT, and the 8 screws at
the opposite end of the polarizer after rotating the polarizer.
Markings in the 2 figures may not be exactly in the positions indicated here but rather serve as
reference when assembling for RHCP or LHCP polarization. If the above procedure did not
solve your problem contact iNetVu support for further assistance.
RHCP
OMT and flange
alignment markings
LNB
Horizontally
orientated
Note: Polarization indicated is the polarization
of the antenna system at transmit. Receive
polarization is opposite.
Polarizer/Diplexer
Rotate Polarizer 90°
align markings