2.6.5 MACHINE SET
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
1. Used to disable the automatic shutdown caused by charge fault.
2. Used to disable the automatic shutdown caused by the gutter fault.
3. used to set the modulation value, auto mode only takes effect during startup.
4. Used to set the charge value.
5. Used to set the running pressure.
6. Used to set the heater target temperature.
7. Used to set the phase charge value.
8. Used to set the phase offset value.
9. Used to check the current software information.
10. Used to define the shortcut function on main screen.
11. Used to enable /disable the keyboard buzzer.
12. Used to set the system time and date, the frozen time setting is in this menu;
13. Used to set the EHT Grade, range 1-3, the higher the value, the lower the sensitivity..
14. Used to set the output range of the 7KV extra high tension which is matched with the
Height value in F3 Parameters.
15. Used to change the gutter mode.
16. Used for serial port configuration.
17. Used to set the printer language.
18. Used to check the maintenance time, and the ink cartridge type (750ml/375ml) can be
selected here.
19. Used to Enable /Disable the backlight Saver.
20. Used to set the font style for 0,1 and 5 (Some fonts will not take effect)
21. Used to calibrate the EHT standard values
22. Used to check the expiration infos for the cartridges.