NV11 Manual Set Section 4 15
Copyright © Innovative Technology Ltd 2012 GA963-2
The NV11 validator leaves the factory preset
to at least one currency and one firmware
interface so that it is ready for immediate
installation.
WARNING!
Risk of unit damage
When in programming mode, do not turn off the
power before the operation is complete as this will
make the unit unusable.
4.8 Programming
Full details on programming the NV11 validator using software can be found in
Section 3 of this manual set (ITL Software Support Guide).
It is not possible to program the NV11 by the use of a configuration card as this
method of programming is not yet implemented.
Action
Power Status
Function
Press and hold (more than
2 seconds) until the bezel
illuminates, then release
Powered ON
Sets validator to Programming
mode (SSP)
Press twice (within half a
second)
Powered ON
Shows current interface type (see
flash count table below)
Press once when Note
Float module status LED is
flashing (transport error)
Powered ON
Acknowledges that a note
blockage has been cleared
Flash Count
Interface
1
SSP
6
ccTalk
6 , 1
ccTalk plain (16 bit)
6 , 1 , 2
ccTalk (8 bit)

Table of Contents