NV11 Manual Set Section 5 17
Copyright © Innovative Technology Ltd 2012 GA963-2
ccTalk Command Summary
Command
Header
Parameters
Example
Reset Device
001
None
ACK
Request Comms
Revision
004
None
X.Y
Force Empty NV11
Store to Cash Box
019
SEL
EVENT
Request Expanded
NV11 status
020
SEL
FLAG, EVENT,
REMAIN, PAID,
UNPAID, STORED,
STORE, FLAG2
Clear Total Count
021
SEL
ACK / NAK
Pump RNG
022
R1-R8
ACK
Request Cipher Key
023
None
KEY1 KEY8
Request Variable
Set
024
SEL
KEY, MC
Modify Variable Set
025
SEL, KEY
ACK
Request Total
Count
026
SEL
IN1-IN3, OUT1-
OUT3, STR1-STR3
Enable Payout
027
KEY
ACK / NAK
Dispense NV11
Notes
028
SEL, SEC1-SEC8,
BILL CNT
EVENT / NAK
Request NV11
Status
029
SEL
FLAG, EVENT,
REMAIN, PAID,
UNPAID, STORED,
STORE
Emergency Stop
030
SEL, FUNC
REMAIN
Empty NV11 Store
to Cash Box
031
SEL
EVENT
Modify Variable MC
Set
032
SEL, MC
ACK / NAK
Request RC Version
033
SEL
VERSION
Request RC Count
034
SEL
COUNT
Modify RC Count
035
SEL, COUNT
ACK / NAK
Request Current
Count
036
SEL
COUNT
Read Barcode Data
129
None
ACK
Store Encryption
Code
136
None
ACK
Switch Encryption
Code
137
3 bytes Encryption
key
ACK
Request Currency
Revision
145
None or Country
Code (2 digit)
‘GBP02113’
Operate Bi-
directional Motors
146
None
ACK
Stacker Cycle
147
None
ACK
Request Bill
Operating Mode
152
None
3