Commissioning and Trial Run
58
Parame
ter
Code
Parameter
Name
Value Range Default Description
F1‑37 Auto‑tuning
mode
0: No operation
1: Static auto‑tuning on
partial parameters of
asynchronous motor
2: Dynamic auto‑tuning
of asynchronous motor
3: Static auto‑tuning on
all parameters of
asynchronous motor
4: Inertia auto‑tuning
5: Dead zone auto‑
tuning
11: With‑load auto‑
tuning of synchronous
motor (excluding back
EMF)
12: No‑load dynamic
auto‑tuning of
synchronous motor
13: With‑load rotary
auto‑tuning of
synchronous motor
(excluding zero point
angle)
14: Auto‑tuning on gain
difference between U‑
phase and V‑phase
15: MTPA of reluctance
motor
0
A9‑40 Torque point
4 of friction
curve
‑320.00 N·m to 320.00
N·m
0.00
N·m
A9‑41 Torque point
5 of friction
curve
‑320.00 N·m to 320.00
N·m
0.00
N·m
A9‑42 Torque point
6 of friction
curve
‑320.00 N·m to 320.00
N·m
0.00
N·m
A9‑43 Torque point
7 of friction
curve
‑320.00 N·m to 320.00
N·m
0.00
N·m