14. Boxboard Configuration Label has incorrect NIC1 and NIC2 order.
NIC1 is the upper NIC
Problem Boxboard Configuration Label has incorrect NIC1 and NIC2 order. NIC1
is the upper NIC.
Implication The wrong configuration label may confuse some channel customers.
Workaround Intel® Server Board SE7520BD2 C71063-005 and below will be fixed in
WW10 with C71063-006 and with label C71061-005
Intel® Server Board SE7520BD2SCSI C71062-005 and below will be
fixed in WW10 with C71062-006 and with label C71061-005
Intel® Server Board SE7520BD2V C76556-005 and below will be fixed
in WW10 with C76556-006 and with label C71901-005
Status Intel will fix this problem with new labels.
15. System fault LED glowing continuously Fab605 board.
Problem The onboard system fault LED continuously glows on the Fab605
board.
Implication Customers may feel that the LED is working abnormally and that the
board may have problems when actually the board is OK. The problem
is caused by software. IMM firmware and FRUSDR that is too old will
cause this error.
Workaround Customer needs to update the IMM module firmware to 0.36 version if
IMM is used, then update FRUSDR to 6.5.2. If IMM is not used, then
update the FRUSDR to 6.5.2 directly.
Status The updated FRUSDR is available from the SUP that is posted to the
IBL website.