4.3.5 FRU Information
The platform management architecture supports providing FRU (Field Replaceable Unit)
information for the baseboard and major replaceable modules in the chassis. ‘Major Module’ is
defined as any circuit board in the system containing active electronic circuitry.
FRU information includes board serial number, part number, name, asset tag, and other
information. FRUs that contain a management controller use the controller to provide access to
the FRU information. FRUs that lack a management controller can make their FRU information
available via a SEEPROM directly connected to the mBMC’s sensor device private I
2
C bus. This
allows the system integrator to provide a chassis FRU device without having to implement a
management controller. This information can only be accessed via IPMI Master Write-Read
commands.
The mBMC implements the interface for logical FRU inventory devices as specified in the
Intelligent Platform Management Interface Specification, Version 1.5. This functionality provides
commands used for accessing and managing the FRU inventory information associated with the
baseboard (FRU ID 0). These commands can be delivered via all interfaces. All other FRUs
must be accessed using IPMI Master Write-Read commands.
4.3.5.1 mBMC FRU Inventory Area Format
The mBMC FRU inventory area format follows the Platform Management FRU Information
Storage Definition. Refer to Platform Management FRU Information Storage Definition, Version
1.0 for details.
The mBMC provides only low-level access to the FRU inventory area storage. It does not
validate or interpret the data stored in the FRU memory.
The baseboard’s FRU information is kept in the mBMC internal flash memory.
4.4 Sensors
4.4.1 Sensor Type Codes
The following tables list the sensor identification numbers and information regarding the sensor
type, name, supported thresholds, assertion and deassertion information, and a brief description
of the sensor purpose. Refer to the Intelligent Platform Management Interface Specification,
Version 1.5, for sensor and event/reading-type table information.
Sensor Type
The Sensor Type references the values enumerated in the Sensor Type Codes table in
the IPMI specification. It provides the context in which to interpret the sensor, e.g., the
physical entity or characteristic that is represented by this sensor.
Event/Reading Type
The Event/Reading Type references values from the Event/Reading Type Code Ranges
and Generic Event/Reading Type Codes tables in the IPMI specification. Note that digital
sensors are a specific type of discrete sensors, which have only two states.
Event Offset/Triggers
Event Thresholds are supported event generating thresholds for threshold types of
sensors.

Table of Contents

Other manuals for Intel SE7520BD2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intel SE7520BD2 and is the answer not in the manual?

Intel SE7520BD2 Specifications

General IconGeneral
BrandIntel
ModelSE7520BD2
CategoryServer Board
LanguageEnglish

Related product manuals