What to do if my Interacoustics OtoRead displays 'Memory Full!'?
- OOscar MiddletonAug 26, 2025
You will need to clear the memory before performing any additional tests.

What to do if my Interacoustics OtoRead displays 'Memory Full!'?
You will need to clear the memory before performing any additional tests.
What to do if Interacoustics OtoRead Medical Equipment display is frozen?
If the display is frozen and the instrument does not respond when you press a button, press and hold the DOWN arrow button for 10 seconds to force the instrument to power off. Powering the instrument back on should reset and restore normal function.
What to do if Interacoustics Medical Equipment shows 'Printer Error'?
Check the printer status, reset the printer, or cycle the printer power.
What to do if Interacoustics Medical Equipment displays 'Device Not Responding'?
Check the printer status. Awaken the printer from sleep mode, and charge the printer battery if necessary.
Why Interacoustics OtoRead Medical Equipment test will not start?
If the test will not start, try these steps: 1. Select a different sized ear tip. 2. Reposition the probe. 3. Change the probe tube. 4. Verify that the ear tip is sealed in the ear canal via feedback from the PROBE CHECK screen. 5. Check that the instrument will start in your own ear with the proper ear tip for testing yourself. If the test still won't start or if the AutoStart tones sound unusual, replace the probe tube.
What to do if Interacoustics Medical Equipment displays 'BT Device Not Found'?
The paired wireless device cannot be detected because the device may be turned off or too far away. Check that the printer is turned on, move closer to the printer, and try again.
What to do if Interacoustics OtoRead Medical Equipment displays 'Memory almost full'?
To prevent interruptions during testing, print or transfer the test results to a PC.
How to fix 'Fit Error Too High' on Interacoustics OtoRead?
Refit the probe in the patient’s ear and retry the test. If the issue persists, replace the probe tube.
How to fix 'Fit Error Too Low' on Interacoustics OtoRead Medical Equipment?
Refit the probe in the patient’s ear and retry the test. If the issue persists, replace the probe tube.
What to do if Interacoustics Medical Equipment displays 'Limit Error'?
If you see a Limit Error, repeat the test. If the error persists, cycle the instrument power.
| Brand | Interacoustics |
|---|---|
| Model | OtoRead |
| Category | Medical Equipment |
| Language | English |
Covers electrical, explosion, EMC, environmental safety, and general cautions.
Details instrument components, probe, hook, neckstrap connections.
Instructions for cradle installation, use, and battery charging procedures.
General precautions, control panel, powering device on/off, and battery status.
Explains LED indicators, daily system checks, and patient preparation steps.
Guidance on ear tip selection, attachment, removal, and probe tube management.
Lists common problems and their solutions for the instrument and printer.