Chapter 4: Menu reference
CDC4 Door Controller Installation and Programming Manual 93
The allowed values are 0 to 65 532. 0 means no limit.
Below Low limit Output BUS
The defined output is active when the number of users in the region is below the
value programmed in “Low limit” on page 92. The option is disabled if the Low
limit value is set to 0.
High Limit
The maximum number of users required in the selected region. When the
number of users reaches the programmed value, the output defined in “High
Limit Output BUS” below activates.
The allowed values are 0 to 65 532. 0 means no limit.
High Limit Output BUS
The defined output activates when the number of users in the region reaches the
value programmed in “High Limit” above. The option is disabled if the High limit
value is set to 0.
Minimum HSU
The minimum number of high security users (HSU) required in the selected
region.
The option is similar to “Low limit” on page 92, but applies to high security users.
Below Minimum HSU Output BUS
The defined output is active when the number of high security users in the region
is below the value programmed in “Minimum HSU” above.
The option is similar to “Below Low limit Output BUS” above, but applies to high
security users.
Maximum HSU
The maximum number of HSU required in the selected region.
The option is similar to “High Limit” above, but applies to high security users.
Maximum HSU Output BUS
The defined output activates when the number of high security users in the
region reaches the value programmed in “Maximum HSU” above.
The option is similar to “High Limit Output BUS” above, but applies to high
security users.
HSU Warning Time
The time (in seconds) for the warning timer. When the number of high security
users is below the minimum, the warning timer starts.
The timer resets if the number of HSU increases to the minimum threshold.