24 NX-595E User Manual
Menu 2 - S
y
stem Control
2.1 Security System Status
2.2 Partition Control
2.3 To Control Zone Bypass
2.4 Event History
Bypassing
The zone bypass menu is used to bypass (isolate) selected zones in your
security system. A bypassed zone is not capable of activating an alarm, as it is
temporarily removed from your system. Bypassing zones lowers your level of
security and caution should be exercised. All bypassed zones are reset and
cleared from memory when your security system is next armed / disarmed. Your
security system must be disarmed (turned off) before being able to bypass
zones. After bypassing your selected zones, your security system must be armed
(turned On) in either the away or stay mode to secure the remaining zones
How to: Bypass zones within your security system
Step Example:
Away Arm, Stay Arm or Disarm partitions within a Multi partition
system
1.
[PIN] Call the NX-595E via an offsite touch-tone phone to begin the session.
2.
Press [2] for system control menu.
Press [3] to control zone bypass.
3.
To control zone bypass, select a zone number followed by #.
4.
Press 0, to bypass/un-bypass.
(Toggles zone from un-bypassed to bypassed Or if already bypassed, from
bypassed to un-bypassed.)
5.
1
st
star, moves back to system control menu.
2
nd
star, moves back to main menu.
# Disconnects session.
Menu 2 - S
y
stem Control
2.1 Security System Status
2.2 Partition Control
2.3 To Control Zone Bypass
2.4 Event History
System Event History
The Event History menu is used to listen to the last 185 events that occurred in
your security system. These events are held within your security system, and
include events such as, arming, disarming, system faults and alarmed zones. All
events are time date stamped, so ensure your clock is set correctly. Alarm

Table of Contents

Other manuals for Interlogix NX-595E

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Interlogix NX-595E and is the answer not in the manual?

Interlogix NX-595E Specifications

General IconGeneral
Quantity1
CompatibilityV2 (NX-4, NX-6, NX-8, NX-8E, NX-7, NX-9, NX-10, NX-11)
Operating temperature (T-T)0 - 49 °C
Weight and Dimensions IconWeight and Dimensions
Depth90 mm
Width220 mm
Height45 mm
Weight130 g
Dimensions (WxDxH)220 x 90 x 45 mm