NX-595E User Manual 53
Check that other devices on the same network can connect to the internet, if
they are working then confirm all access codes are correct (serial number,
Web Access Passcode, username, PIN)
System Status Messages
Zone Number / Zone Name
In alarm – This zone has triggered a system alarm condition
Is bypassed – This zone is isolated (disabled) and will not activate an alarm
Chime is set – This zone is part of the chime group
Is not secure – This zone is not closed
Fire alarm – This zone has triggered a fire alarm
Tamper – This zone has triggered a tamper alarm
Trouble fault – This zone has an open circuit
Loss of wireless supervision – This zone is a wireless device and has lost its communication link
with the control panel
Low battery – This zone is a wireless device and needs its battery changed
Partition Number / Partition Name
Is on in the away mode – This partition is armed in the away mode
Is on in the stay mode – This partition is armed in the stay mode
Is ready – This partition is secure and ready to be armed
Is not ready – This partition is NOT ready to be armed, a zone is not secure
All partitions are on in the away mode – All partitions in this multi partition system are armed in
the away mode
All partitions are on in the stay mode – All partitions in this multi partition system are armed in the
stay mode
All partitions are ready – All partitions in this multi partition system are secure and ready to be
armed
System
AC power fail – The security system has lost its electricity power
Low battery – The security systems back up battery requires charging
Battery test fail – The security systems back up battery requires changing
Box tamper – The security systems cabinet tamper input has activated
Siren trouble – The security systems external siren has a problem
Over current – The security system is drawing too much current
Time and date loss The security system time and date need resetting
Communication fault – The security system has detected a problem with the phone line

Table of Contents

Other manuals for Interlogix NX-595E

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Interlogix NX-595E and is the answer not in the manual?

Interlogix NX-595E Specifications

General IconGeneral
Quantity1
CompatibilityV2 (NX-4, NX-6, NX-8, NX-8E, NX-7, NX-9, NX-10, NX-11)
Operating temperature (T-T)0 - 49 °C
Weight and Dimensions IconWeight and Dimensions
Depth90 mm
Width220 mm
Height45 mm
Weight130 g
Dimensions (WxDxH)220 x 90 x 45 mm