22 ZeroWire Reference Guide
Strobe on Away
If enabled, the system strobe will flash when an area is set in away mode. The
strobe outputs must be configured to follow the area alarm event condition. The
strobe is not activated on Disarm or Stay.
System Alarm Latch
If enabled, system alarms such as tampers, low battery, A/C fail and trouble
requires a user with “Reset System Alarms” enabled in their current Permission
Options to reset the alarm condition.
If disabled, system alarms do not latch and can be reset when a user arms or
disarms an area.
Zone Inactivity
If enabled, the system ZeroWire will monitor each zone for activations. If no
activations occur within the zone activity time then a failed zone activity report
may be reported via the selected communication channel and a failed zone
activity message set in the ZeroWire event log. For a zone to be eligible for
activity monitoring, it must have “Zone Activity” set in zone options. The zone
inactivity time is set in “Menu 2 – System Options - 3. System Timers”
System Timers
Siren Time
The siren time sets the time in minutes that the siren output is active.
Strobe Time
The strobe time is the duration in hours that output programmed to follow the
strobe time will activate. The valid time selection in this segment is 0 to 99 hours,
where ‘0’ disables the Strobe Output.
Battery Test Time
The battery test time sets the duration in minutes that the ZeroWire will perform a
battery test. The ZeroWire will perform a battery test at the disarming of the first
area or at midnight once each 24-hour cycle. Battery Test Time is disabled when
the test duration is set to 0. Battery Test Time can also be run manually from a
keypad.
AC Failure Report Delay
The AC failure report delay sets the duration in seconds that the AC power is lost
or restored before a communication is initiated.
AC restore will report when power is maintained for this same duration.
Twin Trip Time
The Twin Trip time sets the duration in seconds whereby two or more zones
must trip before an alarm condition will be registered or the one zone must trigger

Other manuals for Interlogix ZeroWire

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Interlogix ZeroWire and is the answer not in the manual?

Interlogix ZeroWire Specifications

General IconGeneral
BrandInterlogix
ModelZeroWire
CategorySecurity System
LanguageEnglish

Related product manuals