ZeroWire Reference Guide 51
Action Number
The ZeroWire can support a total of 32 Actions. Each Action is identified by a
unique number, which cannot be altered, and remains as the key reference for
each Action.
Action Name
Each Action can be configured with a custom 32-character name. The name is
displayed wherever an Action is referenced on the ZeroWire system.
Function
Timed
The action state turns on for the time specified.
Follow
The action state turns on once the Event conditions have been satisfied, then off
once the Event conditions are not true.
On Delay
The action state becomes on after the programmed time period unless logic
result is no longer active.
Off Delay
Follows the result of the logic equation, but remains active for the time
programmed after the logic result is no longer active.
Pulsed
Action state turns on for the programmed time or the active period of the logic
result, whichever is the SHORTEST.
Latch
The action state stays on once the Event conditions have been satisfied
Duration Minutes
Where the Function requires duration, this determines how long the action should
stay on for in minutes.
Duration Seconds
Where the Function requires duration, this determines how long the action should
stay on for in seconds.