ZeroWire Reference Guide 33
Force Arm With Bypass
If enabled, the area can be armed even if zones are not ready. Any zones that
are not ready will automatically be bypassed, log the bypass, and optionally
report the bypass.
The automatic bypass will be applied when the zone is capable of causing an
alarm condition due to a state change such as an area arming, schedule or
action. This avoids false alarms.
If an auto-bypassed zone becomes ready after it is armed, that zone will
automatically remove the bypass, log the bypass restore, and optionally report
the bypass restore.
Individual zones can be made “force armable with auto-bypass” by leaving this
area option off, then enabling Forced Arm Enable in Zone options, and enabling
Zone Inhibit in the Zone Type Profile.
Force Arm Without Bypass
If enabled, the area can be armed even if zones are not ready. Any zones that
are not ready will NOT be automatically be bypassed and may cause an alarm
condition because they could still be in a not ready state once the area becomes
armed.
This option is overridden if the Force Arm With Bypass is enabled.
Individual zones can be made “force armable without auto-bypass” by leaving
this area option off, then enabling Forced Arm Enable in Zone options, and
disabling Zone Inhibit in the Zone Type Profile.
Silent Exit
If enabled, ZeroWire not sound the exit warning beeper.
Manual Fire
If enabled, the manual fire button will be enabled on keypads. Press and hold for
2 seconds to send a fire event. Default is off.
If disabled, on selected models will enable the Fire button on the ZeroWire
keypad to send a Key A event which can be used for automation programming in
Scenes.
Manual Auxiliary
If enabled, the manual auxiliary button will be enabled on keypads. Press and
hold for 2 seconds to send an auxiliary event. Default is off.
If disabled, on selected models will enable the Medical/Auxiliary button on the
ZeroWire keypad to send a Key B event which can be used for automation
programming in Scenes.
Manual Panic
If enabled, the manual panic button will be enabled on keypads. Press and hold
for 2 seconds to send a panic event. Default is off.