ZeroWire Reference Guide 65
Report Arm-Disarm Exceptions
When enabled all four reports are sent as appropriate.
Early Opening
‘Fail To Open’ and the reset report ‘Late Open’
Early Close
‘Fail To Close’ and the reset report ‘Late Closing’
When this setting is disabled, only reports ‘Fail To Open’ and ‘Fail To Close’ are
sent with their respective resets ‘Late Open’ and ‘Late Close’. Both the ‘Early
Open’ and ‘Early Close’ reports are suppressed.
‘Fail To Open’ and the reset report ‘Late Open’
‘Fail To Close’ and the reset report ‘Late Closing’
See Area Type for more details.
Log PIN Use
Log will show "Valid Code Entered" when enabled. Must be enabled to allow
actions and scene events to monitor user interaction.
Area User Timers Options
Disarm Time
Man Down Time
Guard Tour Time
These timers apply to a user when allocated this permission and:
the Area Type is set to Timed Disarm, Man Down, or Guard Tour,
is inside Area Type schedule,
and Area Type Override is NOT enabled under Permission Options.
If the value of the associated timer is zero, then the system will apply a timer of
45min.
See Menu 4 Areas, Area Type Settings for a more detailed description on
these features.

Other manuals for Interlogix ZeroWire

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Interlogix ZeroWire and is the answer not in the manual?

Interlogix ZeroWire Specifications

General IconGeneral
BrandInterlogix
ModelZeroWire
CategorySecurity System
LanguageEnglish

Related product manuals