64  ZeroWire Reference Guide 
Stay Arm Area Group 
This controls what areas can be stay armed. 
Permission Options 
Remote Access 
Enables and disable remote web access to the permission.  If this is not enabled, 
a user will not be able to access the web interface directly or via a smartphone 
app. 
Duress Code 
Designates this user as a duress code, whenever this code is entered on the 
ZeroWire keypad a duress message is sent. 
Reset System Alarms 
When System Option - System Alarm Latch is enabled, system alarms include 
panel box tamper can only be reset by a user with this permission. Users without 
this permission will be able to arm and disarm areas as normal, but system 
alarms will stay latched. 
Auto Un-Bypass 
When enabled, a bypassed zone will be reset when disarming.  When disabled, 
the zone will remain bypassed even after the system has been disarmed. 
Disarm Area In Alarm 
When disabled, this user will not be able to disarm and reset an area in alarm. 
Even if the user has permission in their Disarm Area Group, this option will 
override disarm authority.   
Area Type Override 
Applies to non-standard area types 'Time Disarm' 'Man Down' 'Guard Tour'. 
When set, disables the feature for the user. 
Disarm Action Trigger 
When enabled, this user will trigger the Action trigger event “User Disarm 
Trigger” when disarming an area, used for programming actions. 
Arm Action Test 
When enabled, this user will trigger the Action trigger event “User Arm Trigger” 
when arming an area, used for programming actions. 
Report Arm/Disarm 
Where a system is already configured to send Arm-Disarm reports this option 
allows a user to NOT send a report.  When enabled, the reports will be sent.  
When disabled, reports will not be sent.