74 ZeroWire Reference Guide
Menu 16 - Zone Options
Zones are fully configurable in the ZeroWire panel. These features are
considered advanced programming and should only be changed with a thorough
understanding of the operation of each bit.
Zone Option Number
The ZeroWire can support a total of 32 Zone Options. Each Zone Option is
identified by a unique number, which cannot be altered, and remains as the key
reference for each Zone Option.
Zone Options Name
Each Zone Option can be configured with a custom 32 character name. The
name is displayed wherever a Zone Option is referenced on the ZeroWire
system.
Zone Options
Bypassed Stay Mode
If enabled, this zone is automatically bypassed when the area is armed in stay
mode. For example, it is an interior zone.
Force Arm Enabled
If enabled, this zone type may be unsealed while arming if forced arming is
enabled in the area options. Normally all zones in an area must be sealed before
a user can attempt to arm that area.
Bypass
If enabled, this zone may be bypassed.
Twin Trip
This zone type will require two triggers or another zone would have to have been
trigged before it will activate an alarm.
EOL
Enable End Of Line resistor tamper monitoring.
Automatic Zone Test
If enabled, this test is controlled by action results automatic test on and off.
Night Mode
If enabled, sensor is bypassed in Stay Mode or Instant Stay Mode, and active in
Stay Night Mode.