ZeroWire Reference Guide 75
Zone Inactivity Test
If enabled, this zone will check for Zone Inactivity. The Zone Inactivity setting
must be enabled under System Options > General Options. And the time is
programmed in System Options > System Timers > Zone Inactivity Time.
Follow Any Armed Area
If enabled, and a zone is in more than 1 area it will create an alarm if triggered
when any area is armed. If this feature is off then all the areas must be armed
before the zone will become active.
If zone is type 10 zone (Interlogix Door/Window detector) then these two options
apply:
• Disable Internal Reed Switch – tick this box when using external contacts.
• Normally Open External Contact – tick this box when external contact is
normally open.
These two options appear in the Web Server – Settings – Zones page.
Table 5: Default Zone Options