Page #42 background imageLoading...
Page #42 background image
42 ZeroWire Reference Guide
Menu 6 - Communicator
The ZeroWire Communicator is a core component of the ZeroWire System used
in conjunction with the Channels feature to report events to a monitoring
company or third party. In this menu you can configure the settings for various
methods of reporting.
General Options
First Disarm Last Arm
If enabled, the ZeroWire will only send a closing report when the last area is
armed. Note: the last area to arm must have open/close reports enabled. The
ZeroWire will only send an opening report when the first area is disarmed.
This feature is used in place of Individual area Open and close. If you enable
open and close in the area you will get both individual open and close and
System open close
Report Once Per Zone
If enabled, this will limit reporting to only once per zone each time you arm or
disarm an area. This stops the control room or reporting destination to be flooded
by multiple reports that the same zone is being activated (for example the
intruder may be moving around and is being picked up by the zone on that zone.)
Suppress Force Arm Bypass
If enabled, the ZeroWire does not send bypass reports when a zone is forced
armed.
If not enabled, when a zone is forced armed and it remains in a state of creating
an alarm, bypass reports are sent at the end of exit time. For example this would
occur if it remains unsealed at the end of the exit time, or due to change of zone
type caused by a schedule.
If forced armed zones re-seal during the armed period, bypass restores are sent.
Immediate Restore
If enabled, the ZeroWire will immediately send all restores as the zone reports
the event.
If not enabled, the ZeroWire will send restoral events all at the same time when
the area is disarmed.
Auto Test
Auto Test Intervals
Set day of the week to send an automatic test report to the system channel group
(Communicator\System Event Reporting\System Channels). You may also set
auto-test to Daily.

Other manuals for Interlogix ZeroWire

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Interlogix ZeroWire and is the answer not in the manual?

Interlogix ZeroWire Specifications

General IconGeneral
BrandInterlogix
ModelZeroWire
CategorySecurity System
LanguageEnglish

Related product manuals