24 ZeroWire Reference Guide
Zone Inactivity Time
Zones programmed with Zone Inactivity enabled in the Zone Options must be
sealed and unsealed within the time programmed here (in minutes). If they do
not, a Zone Inactivity will report.
This system feature can be enabled in “Menu 2 – System Options”. Then,
enabled per zone under Zone Options.
Zone Inactivity option is disabled for all default Zone Options, and this timer is set
to 0 minutes.
Fire Supervise Time
This applies only to wireless zones programmed as fire type. Detectors send a
reduced packet count supervisory signal every 60 minutes (check your detector
manual for most up to date details). If no supervisory signal is received by the
panel within the time specified here then the detector will be reported as missing.
When set to 0 the default of 14,400 seconds (4 hours) will be used. Check your
local regulations for the correct value to use.
Burglary Supervision Time
This applies only to wireless zones programmed as non-fire type. Detectors send
a reduced packet count supervisory signal every 15 minutes (check your detector
manual for most up to date details). If no supervisory signal is received by the
panel within the time specified here then the detector will be reported as missing.
When set to 0 the default of 43,200 seconds (12 hours) will be used. Check your
local regulations for the correct value to use.
Short Supervision Time
This applies only to wireless zones programmed as non-fire type. Detectors send
a reduced packet count supervisory signal every 15 minutes (check your detector
manual for most up to date details). If no supervisory signal is received by the
panel within the time specified here, then a local zone supervision fault will be
displayed, this is NOT reported to a control room until the Burglary Supervision
Time above elapses. The default is 20 minutes.
Siren Options
Siren Once Per Zone
If enabled, the ZeroWire will only set the siren once per zone in a given arm cycle
and will not set the siren again even if that siren time expires and that zone
reactivates. Every zone will have one siren activation attempt before that zone
cannot reactivate the siren. If this option is not enabled, at the expiry of the siren
time any zone can reactivate the siren an unlimited number of times.

Other manuals for Interlogix ZeroWire

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Interlogix ZeroWire and is the answer not in the manual?

Interlogix ZeroWire Specifications

General IconGeneral
BrandInterlogix
ModelZeroWire
CategorySecurity System
LanguageEnglish

Related product manuals