34 ZeroWire Reference Guide
If disabled, on selected models will enable the Police button on the ZeroWire
keypad to send a Key C event which can be used for automation programming in
Scenes.
Use Area 1 Options
If enabled, the area will use Area 1 options. Default is on.
Bypass Requires PIN
If enabled, a valid PIN code with access to this area is required to bypass zones
in this area.
Manual Panic is Silent
If enabled, manual panic alarms will not trigger an audible alarm.
Arm In Instant If No Exit
If enabled, will arm panel in instant mode (no entry delay) after the exit timer
expires and no Entry/Exit zones are tripped. This assumes the person arming the
system did not leave, and is still within the protected area. This provides greater
security because any attempt to enter the area even through a designated
Entry/Exit zone will trigger an instant alarm.
Area Timers
Auto Arm Warning
If the area type is Standard and Arm / Disarm is configured, this timer delays
arming by the minutes entered.
If the area type is Timed Disarm, Man Down, or Guard Tour, this setting is a
warning time given to a user once the user’s Disarm Time, Man Down Time, or
Guard Tour Time has expired. During this warning time a user can cancel the
automatic re-arming and event report by entering their code, this will also restart
the appropriate user timer. At the end of the warning time the ZeroWire will re-
arm the area and send the appropriate event (closing, man down, guard tour fail).
If the area type is Early Open & Late Close, this timer sets the period after the
start (opening) and after the end (closing) of the area type schedule that the area
can be disarmed or armed. Otherwise an early to open or late to close report will
be sent if enabled in user permissions. Fail to open and fail to close report will be
sent if Arm-Disarm Reports is enabled in area options.
Valid values are from 0 to 99 minutes.
Local Alarm Reminder
If set, the local alarm reminder is the period in hours between 0 and 12 that may
elapse between starting a local alarm and the local alarm reactivating if that zone
has remained open.
For example, the tamper will trip if a smoke detector is removed to change the
battery; if a user resets the alarm on the xGen but does not replace the smoke