ZeroWire Reference Guide 29
If the first zone profile’s schedule is not active then it will check the second zone
profile. If the schedule is active then that profile is applied to that zone.
User Number
The zone user number feature is used whenever the zone type is set to
“keyswitch”. Users are configured in Menu 1 – Users. One of 40 configurable
users can be allocated to any zone’s user number. ZeroWire zone profile user
number is a powerful feature that is used to apply the selected users attributes to
a keyswitch operation. When the keyswitch is activated, ZeroWire will check the
user permissions and permission schedules to determine which areas are
accessible. Additionally, area open and close reports will also report the user
number selected in this option. If the user number is programmed to 0, the
ZeroWire will use a default User number of 999 and will operate on all areas in
the zones area group.
Second Zone Profile
Refer to the first zone profile.
Zone Type
Refer to first zone profile.
Zone Options
Refer to first zone profile.
Area Group
Refer to first zone profile.
Schedule Number
Refer to first zone profile.
User Number
Refer to first zone profile.