ZeroWire Reference Guide 71
Keyswitch: A momentary key switch can be used to arm/disarm the panel
when it is momentarily shorted from a sealed condition.
Use a 3.3K resistor for this zone type. Or, if DEOL monitoring is enabled in
System Options, use two 3.3K resistors to allow full line monitoring.
Event Only: This zone only creates an event when tripped and is stored
in the event log.
Siren Attribute
Select from these 4 options to control what sound the siren makes when this
zone goes into alarm.
Silent: siren makes no sound
Steady: constant siren sound
Yelping: siren makes a yelping sound
Pulsing: siren pulses on and off
Zone Attribute Options
Keypad Sounder: If enabled, the panel will announce alarm, tamper, or
trouble conditions. Default is on.
Report Delay: If enabled, the panel will delay reporting zone activations
until the next scheduled report. This setting is ignored if the zone is a Fire
type and zone activations are reported immediately. When disabled zone
activations (trip, bypass and restores) are reported immediately. Default is
off.
No Keypad Display: If enabled, any zone conditions, such as alarm and
tamper, will not illuminate the Alarm Light. Conditions will still report and
function as normal. Default is off.
Momentary Switch: If enabled, the zone will not latch. If it is triggered
again then it will send another report immediately. Default is off.
Zone Inhibit: This feature is designed to reduce false alarms at
arming/disarming. If enabled, a zone that is currently faulted that could
cause an alarm condition will be temporarily bypassed when changing
armed states.
This typically occurs when forced arming and the zone is unsealed, or
when a schedule change occurs that changes the zone type. The bypass
will be applied to the zone if it remains unsealed at the end of the exit
timer.
“Inhibit” is removed when the zone restores at any time. This is different to
a bypass, which is only removed at disarm.
Default is off.
Swinger Shutdown: Default is off.