EasyManua.ls Logo

INVT DA180-S4R5SG0

INVT DA180-S4R5SG0
316 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DA180 series basic AC servo drive Function codes
-107-
P1.25
Depth of notch filter
1
Setting range
Default
Unit
Applicable
mode
0100
0
%
P
S
T
This parameter specifies the amplitude attenuation rate of notch filter 1.
A large value of this parameter indicates low notch filter depth and small phase lag.
P1.25
Data size
16bit
Data format
DEC
Modbus address
1250, 1251
CANopen address
0x2119, 0x00
P1.26
Frequency of notch
filter 2
Setting range
Default
Unit
Applicable
mode
505000
5000
Hz
P
S
T
P1.27
Q factor of notch
filter 2
Setting range
Default
Unit
Applicable
mode
0.5016.00
1.00
-
P
S
T
P1.28
Depth of notch filter
2
Setting range
Default
Unit
Applicable
mode
0100
0
%
P
S
T
These parameters specify characteristics of notch filer 2, similar to P1.23, P1.24, and P1.25.
P1.26
Data size
16bit
Data format
DEC
Modbus address
1252, 1253
CANopen address
0x211A, 0x00
P1.27
Data size
16bit
Data format
DEC
Modbus address
1254, 1255
CANopen address
0x211B, 0x00
P1.28
Data size
16bit
Data format
DEC
Modbus address
1256, 1257
CANopen address
0x211C, 0x00
P1.29
Frequency of notch
filter 3
Setting range
Default
Unit
Applicable
mode
505000
5000
Hz
P
S
T
P1.30
Q factor of notch
filter 3
Setting range
Default
Unit
Applicable
mode
0.5016.00
1.00
-
P
S
T
P1.31
Depth of notch filter
3
Setting range
Default
Unit
Applicable
mode
0100
0
%
P
S
T
These parameters specify characteristics of notch filer 3, similar to P1.23, P1.24, and P1.25.
P1.29
Data size
16bit
Data format
DEC
Modbus address
1258, 1259
CANopen address
0x211D, 0x00
P1.30
Data size
16bit
Data format
DEC

Table of Contents

Related product manuals