DA180 series basic AC servo drive Function codes
-147-
P4.23*
Emergency stop
command
Setting range
Default
Unit
Applicable
mode
01
0
-
P
S
T
This parameter specifies whether to enable emergency stop for the drive.
Setting
Meaning
[0]
Disable
1
Enable
P4.23*
Data size
16bit
Data format
DEC
Modbus address
1846, 1847
CANopen address
0x2417, 0x00
P4.24*
Vibration control
switching command
Setting range
Default
Unit
Applicable
mode
01
0
-
P
This parameter specifies whether to enable vibration control switching for the drive.
Setting
Meaning
[0]
Disable
1
Enable
P4.24*
Data size
16bit
Data format
DEC
Modbus address
1848, 1849
CANopen address
0x2418, 0x00
6.5.3 Extension and application
P4.30
Stop mode
Setting range
Default
Unit
Applicable
mode
03
0
-
P
S
T
This parameter specifies whether the dynamic brake works when the servo is off and a fault alarm is
reported and determine the servo motor status after the stop.
Setting
Action
During deceleration
After stop
[0]
The motor coasts to stop.
Inertia running kept
1
The motor stops through the
dynamic brake.
Inertia running kept
2
The dynamic brake stops.
Dynamic braking
3
The external dynamic brake
acts.
Dynamic braking
Note:
If P4.30 is set to 1, the dynamic brake works when the motor speed is higher than the setting
(30 r/min by default) of P3.58 and it does not work otherwise. After the motor stops, the dynamic
brake does not work.